U.S. Nuclear Regulatory Commission Operations Center Event Reports For 12/05/2007 - 12/06/2007 ** EVENT NUMBERS ** | !!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!! | Other Nuclear Material | Event Number: 43770 | Rep Org: ENGINEERING & TESTING SERVICES Licensee: ENGINEERING & TESTING SERVICES Region: 1 City: VIRGINIA BEACH State: VA County: License #: 45-25600-01 Agreement: N Docket: NRC Notified By: CHARLIE NABHAN HQ OPS Officer: PETE SNYDER | Notification Date: 11/05/2007 Notification Time: 11:38 [ET] Event Date: 11/04/2007 Event Time: 09:00 [EST] Last Update Date: 12/05/2007 | Emergency Class: NON EMERGENCY 10 CFR Section: 30.50(b)(2) - SAFETY EQUIPMENT FAILURE | Person (Organization): MARIE MILLER (R1) GREG MORELL (FSME) | Event Text TROXLER GAUGE DAMAGE BY BACKHOE On 11/4/07 at around 8:45 a.m. to 9 a.m. a Troxler (Model 3430, S/N 33496) moisture density gauge was being used at a construction site when a backhoe suddenly reversed direction and backed over it. The sealed source in the gauge is in the stored and shielded position. The licensee plans to return the gauge to the manufacturer to determine the extent of the damage and for repair. * * * RETRACTION PROVIDED BY C. NABHAN TO J. KOZAL ON 12/05/07 AT 1325 * * * Upon inspection by the Troxler Corporation the gauge was found in the normal condition with only cosmetic damage. No safety equipment was damaged or found inoperable. Troxler performed a microscopic inspection of the source rod and the neutron source cavity, as well as the plug that secures the source. No defects were found. Therefore, no failure of safety equipment existed at any time. Notified R1DO (Barkley), FSME EO (Burgess) | General Information or Other | Event Number: 43816 | Rep Org: TEXAS DEPARTMENT OF HEALTH Licensee: AVILES ENGINEERING INC. Region: 4 City: HOUSTON State: TX County: License #: L03016 Agreement: Y Docket: NRC Notified By: LATISHA HANSON HQ OPS Officer: JEFF ROTTON | Notification Date: 12/01/2007 Notification Time: 12:43 [ET] Event Date: 12/01/2007 Event Time: 08:45 [CST] Last Update Date: 12/01/2007 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): GREG PICK (R4) DENNIS RATHBUN (FSME) ILTAB (VIA EMAIL) () MEXICO (VIA FAX) () | This material event contains a "Less than Cat 3" level of radioactive material. | Event Text TEXAS AGREEMENT STATE REPORT - STOLEN TROXLER MOISTURE DENSITY GAUGE The State provided the following information via facsimile: "On Saturday, 12/01/07 at 10:45 a.m., the agency was contacted through the 24-hour emergency answering service by the licensee's RSO, reporting the theft of their Troxler, Model 3430 moisture/density (m/d) [gauge]. The RSO reported that the employee was enroute to a job site and stopped at a Valero gas station on Tidwell Road in Houston, TX at approximately 8:45 a.m. to get gas. The employee finished pumping the gas, returned the nozzle to its hook and walked to the back of the bed of his Silver Dodge F1500 pickup truck to check the bracing of the gauge, when he noticed that a vagrant from the bus stop jumped in the truck and began to drive off. The employee banged on the window of the driver side and was subsequently drug alongside the truck for a distance, while the perpetrator sped off, jumped a median and eventually escaped. The RSO reported that the gauge was in its transport case, triple locked, and securely braced in the bed of the truck, but the [keys for the gauge locks] were on the same ring as the truck keys. "The Houston local law enforcement (LLE) were immediately notified and a police report was filed and assigned case # 175693707-U. [Incident Investigation Program (IIP)] instructed the RSO to submit a picture of the gauge to the LLE to assist them in locating the gauge. The RSO was also asked to consider placing an advertisement in the local newspaper offering a reward. IIP informed the RSO that TDSH would submit an email notification to Texas Association of Pawn Brokers (TAPS) with a description of the gauge to possibly assist in its location. Gauge Information: Mfg: Troxler, Model #: 3430, Serial #: 026027 Source information: 1) Cesium-137; 8 milliCuries, Serial #: 75-9095 2) Am-241:Be 40 milliCuries, Serial#: 47-22446 Last Leak lest: Monitoring Services on 08/14/07 THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. | General Information or Other | Event Number: 43818 | Rep Org: NV DIV OF RAD HEALTH Licensee: CITY OF HENDERSON, NV Region: 4 City: HENDERSON State: NV County: License #: 03-14-0116-01 Agreement: Y Docket: NRC Notified By: ERIC MATUS HQ OPS Officer: JEFF ROTTON | Notification Date: 12/03/2007 Notification Time: 12:56 [ET] Event Date: 11/27/2007 Event Time: 13:30 [PST] Last Update Date: 12/03/2007 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): MICHAEL HAY (R4) MICHELE BURGESS (FSME) ILTAB (VIA EMAIL) () | This material event contains a "Less than Cat 3" level of radioactive material. | Event Text NEVADA AGREEMENT STATE REPORT - STOLEN TROXLER MOISTURE DENSITY GAUGE "At approximately 1330 [PST] on Tuesday November 27, 2007, a technician and asst. RSO for the City of Henderson NV, drove away from a jobsite where he had been taking a backscatter density measurement with a Troxler 3440 Nuclear Density Gauge. He left the gauge sitting on the side of the road with the probe unlocked and not in a safe mode. At 1333, he returned to the site to find that the gauge had been removed. The RSO filed a report with Henderson PD [on 11/27/07] and phoned in a report to Nevada Radiological Health Section the following day [11/28/07] at 1010. The gauge [Serial #26655] contains [2] sealed sources: 8 milliCuries Cs-137, and 40 milliCuries Am-241/Be ." The licensee issued a press release (print, radio, and TV) to notify the public of the incident, warn them of the potential danger and ask for the return of the gauge. Nevada Item Number: NV070009 THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. | General Information or Other | Event Number: 43819 | Rep Org: COLORADO DEPT OF HEALTH Licensee: LONGMONT UNITED HOSPITAL Region: 4 City: DENVER State: CO County: License #: 73-01 Agreement: Y Docket: NRC Notified By: JENNIFER OPILA HQ OPS Officer: JOE O'HARA | Notification Date: 12/03/2007 Notification Time: 15:21 [ET] Event Date: 08/08/2007 Event Time: 08:00 [MST] Last Update Date: 12/03/2007 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): MICHAEL HAY (R4) MICHELE BURGESS (FSME) | Event Text AGREEMENT STATE NOTIFICATION - MEDICAL EVENT INVOLVING IODINE 125 SEEDS The State provided the following information via facsimile: "On August 8, 2007 a patient presented to Longmont United Hospital, Colorado Radioactive Materials license #73-01, for implantation of I-125 seeds into the prostate for treatment of adenocarcinoma of the prostate. The Authorized User was Radiation Oncologist [DELETED], MD; the surgeon was [DELETED], MD; the Authorized Medical Physicist was [DELETED], MS. "In the course of the operative procedure, some seeds were placed inferior to the prostate rather than into the gland itself. Due to the misplacement of the seeds, the total dose to the prostate differed from the prescribed dose by more than 20%. "The prescribed dose to the prostate was 160 Gy. A total of 63 0.476U Bard Model STM 1251 [seeds] were implanted. [Total activity 0.3 milliCurie per seed]. Post-implant dosimetry was performed, based on a CT scan of pelvic region. The mean dose to the prostate was 14.4 Gy, the mean dose to the rectum was 44.7 Gy, and the mean dose to the urethra was 73.4 Gy. No other critical structures were substantially irradiated. "At the root of this event was displacement of the prostate gland that was not detected by image guidance caused by substantial peri-prostatic bleeding and hematoma formation. The tissues adjacent to the prostate provided an image with features mimicking the appearance of the prostate, though with non-distinct borders. Due to the bleeding, even these non-distinct borders were expected. In short, enough plausible indicators of correct positioning were present that the surgical team proceeded with the implant until the misplacement of the seeds was discovered. "Due to the unusual circumstances of this specific procedure, no underlying deficiency in the prostate brachytherapy program of this licensee is indicated. The program has since implemented the use of stabilization needles at initiation of the implantation procedure. The primary element deserving of attention lies in the inherent dependence upon the ultrasound image. In such rare cases as this of limited visualization, it may behoove all users to use alternative methods to verify position, such as the digital exam performed on this patient or fluoroscopic visualization of the anatomy. It might be recommended to perform the verification in such circumstances prior to the implantation of any seeds. "The spouse of the patient was informed immediately after the surgical procedure, and the patient was informed when he regained his faculties after anesthesia. The CT scan was performed later that day for dosimetric purposes. "It is understood that the notification provided in this report to your Agency [State of Colorado] should have occurred within 15 days of the event. However, there was miscommunication between the Licensee and the QMP, each thinking that the other had made the report. [Licensee] apologizes for this delay. In the future if such an event should occur, a single person will be appointed to submit a report so that this confusion will not occur again." A total of 23 milliCuries from 63 seeds were implemented during this procedure. A "Medical Event" may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient. | General Information or Other | Event Number: 43822 | Rep Org: TEXAS DEPARTMENT OF HEALTH Licensee: DESERT INDUSTRIAL X-RAY LP Region: 4 City: SAGINAW State: TX County: TARRANT License #: L04590-008 Agreement: Y Docket: NRC Notified By: LATISCHA HANSON HQ OPS Officer: JEFF ROTTON | Notification Date: 12/03/2007 Notification Time: 23:13 [ET] Event Date: 12/03/2007 Event Time: 21:00 [CST] Last Update Date: 12/04/2007 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): MICHAEL HAY (R4) DENNIS RATHBUN (FSME) JEFFREY CRUZ (IRD) BENJAMIN SANDLER (ILTA) MIKE INZER (DHS) MIKE SMITH (DOE) MIKE LAFORTY (FEMA) THREET (EPA) JIMENEZ (USDA) KELLEHER (HHS) | This material event contains a "Category 2" level of radioactive material. | Event Text AGREEMENT STATE REPORT - LOST RADIOGRAPHY CAMERA The licensee's radiography team left the temporary jobsite with their SPEC 150 radiography camera on the tailgate. The camera contained a 24 Curie Ir-192 source. The licensee drove approximately 15 miles down the road prior to remembering the gauge was on the tailgate. It was then noticed that the camera was no longer in the truck. The licensee team is retracing their route in search of the camera and will be contacting the Tarrant County Sheriff's Department to aid in the search. The licensee is not sure if the camera had been secured properly prior to driving down the highway. The route taken was from Tinsley Lane to North Business 287 in Saginaw, TX towards Justin, TX in Tarrant County. Notified NORTHCOM and Mexico via email. Texas Report TX-07-43822 *** UPDATE FROM TEXAS DEPARTMENT OF HEALTH (JISHA) TO HOWIE CROUCH AT 0743 ON 12/04/07 *** The SPEC 150 radiography camera was recovered at 0633 CST. A member of the public found the camera and placed it in the back of his private vehicle. Upon hearing about the lost source on the local news this morning, the citizen turned the camera over to the Fort Worth Fire Department. The camera appears intact and undamaged. Texas Department of Health is responding to the fire department to conduct a survey and inspection of the camera. No overexposures are expected. Notified DHS (Haselton), DOE (Parsons), FEMA (Burckart), USDA (Watts), HHS (Garcia), EPA (Johnson), Mexico (via email), NORTHCOM (via email), R4DO (Hay), FSME EO (Burgess) and ILTAB (Sandler). THIS MATERIAL EVENT CONTAINS A "CATEGORY 2" LEVEL OF RADIOACTIVE MATERIAL Category 2 sources, if not safely managed or securely protected, could cause permanent injury to a person who handled them, or were otherwise in contact with them, for a short time (minutes to hours). It could possibly be fatal to be close to this amount of unshielded radioactive material for a period of hours to days. These sources are typically used in practices such as industrial gamma radiography, high dose rate brachytherapy and medium dose rate brachytherapy. | |