Event Notification Report for July 3, 2002

                         
                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           07/02/2002 - 07/03/2002

                              ** EVENT NUMBERS **

38934  39034  39035  39036  39037  
.
!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38934       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COLUMBIA GENERATING STATIREGION:  4  |NOTIFICATION DATE: 05/21/2002|
|    UNIT:  [2] [] []                 STATE:  WA |NOTIFICATION TIME: 18:59[EDT]|
|   RXTYPE: [2] GE-5                             |EVENT DATE:        05/03/2002|
+------------------------------------------------+EVENT TIME:        15:40[PDT]|
| NRC NOTIFIED BY:  BOB BROWNLEE                 |LAST UPDATE DATE:  07/02/2002|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |LINDA SMITH          R4      |
|10 CFR SECTION:                                 |                             |
|AUNA 50.72(b)(3)(ii)(B)  UNANALYZED CONDITION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNANALYZED CONDITION THAT SIGNIFICANTLY DEGRADED PLANT SAFETY                |
|                                                                              |
| On May 3, 2002, approximately 20 gallons of water was spilled on the floor   |
| of the cable spreading room (CSR).  Some of the water leaked down into rooms |
| below the CSR floor, resulting in an electrical ground on the on the 125-VAC |
| Division 2 battery bus S1-2.  The S1-2 bus remained operable.  It has since  |
| been determined that the pathway for leakage through the floor of the CSR    |
| was cracks in the concrete due to abandoned concrete anchors, and through    |
| shrinkage cracks in the reinforced concrete floor slab.  Shrinkage cracks    |
| are also located in the 525' elevation floor above the Control Room.  These  |
| two floors are considered essential fire rated assemblies and are required   |
| to be "leak tight". These floors have not had a qualified paint/sealant      |
| applied that would render them "leaktight".  Other floors that are fire      |
| rated assemblies are believed to have had the appropriate paint/sealant      |
| applied, but this is being verified.  Should a fire system actuate, or       |
| develop a leak in either the CSR or the room above the Control Room, there   |
| is the potential for leakage through the floors to impact Division 1 or 2    |
| safety-related equipment in the rooms below.  A barrier impairment has been  |
| initiated for the CSR on May 6, 2002 and for the 525' elevation above the    |
| Control Room on May 7, 2002 with compensatory action to include these areas  |
| on an hourly fire/flood tour. With the hourly fire/flood tours in place, the |
| floors of the CSR and the room above the Control Room have been declared     |
| "operable but degraded" per formal assessment of operability, and no longer  |
| represent an unanalyzed condition that significantly degrades plant safety.  |
| The cracks associated with the abandoned anchor bolts have been sealed.      |
| Hourly fire/flood tours remain in effect until both floors have been         |
| properly sealed.                                                             |
|                                                                              |
| The NRC Resident Inspector has been notified of this event.                  |
|                                                                              |
| * * * RETRACTED AT 1600 EDT ON 7/2/02 BY BOB BROWNLEE TO FANGIE JONES * * *  |
|                                                                              |
|                                                                              |
| The licensee is retracting this event notification. It was originally        |
| postulated that due to the prevalence of unsealed concrete cracks, a design  |
| basis flooding scenario would create a significant amount of water leakage   |
| into critical equipment rooms below the floors. After further evaluation it  |
| has been concluded that flooding events in either room would result in       |
| minimal leakage into rooms below, and therefore this condition can not be    |
| characterized as an unanalyzed condition that significantly degrades plant   |
| safety. The CSR floor and the room above the Control Room are "operable but  |
| degraded." Hourly fire/flood tours will remain in effect until both floors   |
| have been properly sealed. The cracks responsible for the observed leakage   |
| for this event have been sealed. Columbia Generating Station will submit a   |
| voluntary Licensee Event Report on this issue due to its generic interest to |
| both the NRC staff and the nuclear industry.                                 |
|                                                                              |
| The licensee notified the NRC Resident Inspector.  The R4DO (Dale Powers)    |
| has been notified.                                                           |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39034       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DUANE ARNOLD             REGION:  3  |NOTIFICATION DATE: 07/02/2002|
|    UNIT:  [1] [] []                 STATE:  IA |NOTIFICATION TIME: 10:47[EDT]|
|   RXTYPE: [1] GE-4                             |EVENT DATE:        05/19/2002|
+------------------------------------------------+EVENT TIME:        11:00[CDT]|
| NRC NOTIFIED BY:  CLARE BLEAU                  |LAST UPDATE DATE:  07/02/2002|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |BRUCE JORGENSEN      R3      |
|10 CFR SECTION:                                 |                             |
|AINV 50.73(a)(1)         INVALID SPECIF SYSTEM A|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       21       Power Operation  |0        Cold Shutdown    |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| RADIATION MONITOR DECLARED INOPERABLE                                        |
|                                                                              |
| While operating in Mode 1, in the process of a controlled shutdown to        |
| perform an elective repair of a condenser tube leak, Division "A" Refuel     |
| Pool Radiation Monitor lost power resulting in a Group 3A Primary            |
| Containment Isolation System (PCIS) actuation.  The Group 3A isolation       |
| function as designed.  Radiation levels in the area of the monitor were      |
| normal and the actuation was considered invalid.                             |
|                                                                              |
| The Radiation Monitor was declared inoperable for maintenance.  The monitor  |
| was declared operable at 1049 CST on 05/20/02 at which time the Group III    |
| isolation was also reset.                                                    |
|                                                                              |
| The NRC Resident Inspector was notified of this event by the licensee.       |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   39035       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  US ARMY                              |NOTIFICATION DATE: 07/02/2002|
|LICENSEE:  US ARMY                              |NOTIFICATION TIME: 10:42[EDT]|
|    CITY:  ABERDEEN                 REGION:  1  |EVENT DATE:        07/01/2002|
|  COUNTY:                            STATE:  MD |EVENT TIME:        19:30[EDT]|
|LICENSE#:  1930563-01            AGREEMENT:  Y  |LAST UPDATE DATE:  07/02/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |PETER ESSELGROTH     R1      |
|                                                |FRED BROWN           NMSS    |
+------------------------------------------------+DALE POWERS          R4      |
| NRC NOTIFIED BY:  JOYCE KUYKENDALL             |                             |
|  HQ OPS OFFICER:  RICH LAURA                   |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NONR                     OTHER UNSPEC REQMNT    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| US ARMY LICENSE VIOLATION INVOLVING A CHEMICAL AGENT DETECTOR                |
|                                                                              |
| The US Army reported that License Item 15 was violated when a technician     |
| attempted to disassemble the cell assembly of a chemical agent detector at   |
| Fort Richardson. The cell assembly contains a radiological source of 300     |
| microcuries of AM-241.  The model number is M43A1.  An investigation was     |
| initiated by the US Army to review this event.  At this time there were no   |
| known personnel contaminations or radiological overexposures.                |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   39036       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  ADAMS CONSTRUCTION COMPANY           |NOTIFICATION DATE: 07/02/2002|
|LICENSEE:  ADAMS CONSTRUCTION COMPANY           |NOTIFICATION TIME: 11:00[EDT]|
|    CITY:  SOUTH BOSTON             REGION:  2  |EVENT DATE:        07/01/2002|
|  COUNTY:                            STATE:  VA |EVENT TIME:        15:40[EDT]|
|LICENSE#:  45-1788701            AGREEMENT:  N  |LAST UPDATE DATE:  07/02/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |LEONARD WERT         R2      |
|                                                |DOUG BROADDUS        NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  RON ROBSON                   |                             |
|  HQ OPS OFFICER:  RICH LAURA                   |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NONR                     OTHER UNSPEC REQMNT    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| DAMAGED TROXLER MOISTURE DENSITY GAUGE                                       |
|                                                                              |
| Adams Construction Company reported that an asphalt roller ran over part of  |
| a Troxler moisture density gauge, model number 4640B, serial number 1752.    |
| The source remained intact and was not leaking.  The gauge was transported   |
| to the asphalt plant located in South Boston, VA.  The gauge will be         |
| examined by Troxler for evaluation and repair.  The gauge contained a source |
| of 8 millicuries of CS-137.                                                  |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   39037       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  POWER RESOURCES                      |NOTIFICATION DATE: 07/02/2002|
|LICENSEE:  POWER RESOURCES                      |NOTIFICATION TIME: 13:34[EDT]|
|    CITY:  GLENROCK                 REGION:  4  |EVENT DATE:        07/01/2002|
|  COUNTY:                            STATE:  WY |EVENT TIME:             [MDT]|
|LICENSE#:                        AGREEMENT:  N  |LAST UPDATE DATE:  07/02/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |BILL JOHNSON         R4      |
|                                                |JOHN HICKEY          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  BILL KEARNEY                 |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NINF                     INFORMATION ONLY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MONITOR WELL EXCEEDED TWO OF ITS THREE UPPER CONTROL LIMITS                  |
|                                                                              |
| Monitor well FM6 in the F well field exceeded two of its three upper control |
| limits (UCLs).   A confirmation sample was collected on July 1, 2002.        |
|                                                                              |
| Date 7/1/02                                                                  |
| Chloride (UCL 18 mg/l)  40 mg/l                                              |
| Conductivity (UCL 1121 umhos/cm)  793 umhos/cm                               |
| Bicarbonate (UCL 230 mg/l)  233 mg/l                                         |
| Uranium (UCL 0.1 mg/l)  0.1 mg/l                                             |
|                                                                              |
| The licensee notified NRC Project Manager (Rick Weller).                     |
+------------------------------------------------------------------------------+
.