Event Notification Report for February 25, 2002

                         
                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           02/22/2002 - 02/25/2002

                              ** EVENT NUMBERS **

38704  38716  38717  38718  38719  38720  38721  38722  

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   38704       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PADUCAH GASEOUS DIFFUSION PLANT      |NOTIFICATION DATE: 02/16/2002|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 11:11[EST]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        02/15/2002|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        22:00[CST]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  02/22/2002|
|    CITY:  PADUCAH                  REGION:  3  +-----------------------------+
|  COUNTY:  McCRACKEN                 STATE:  KY |PERSON          ORGANIZATION |
|LICENSE#:  GDP-1                 AGREEMENT:  Y  |ANTON VEGEL          R3      |
|  DOCKET:  0707001                              |SUSAN FRANT          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  KEVIN BEASLEY                |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|OCBA 76.120(c)(2)        SAFETY EQUIPMENT FAILUR|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SAFETY EQUIPMENT FAILURE - PROCESS GAS LEAK DETECTION FAILURE                |
|                                                                              |
| "At 2200 CST, on 02-15-02 the Plant Shift Superintendent (PSS) was notified  |
| of a failure of the Process Gas Leak Detector (PGLD) system in the C-333     |
| building.  During above atmospheric operation a PGLD alarm was received in   |
| the Area Control Room [ACR] on C-333 Unit 4 Cell 4.  An operator responded   |
| to the local cell panel to investigate according to the alarm response       |
| procedure.  Upon arriving at the cell panel the operator discovered that the |
| Ready light was not Illuminated on the PGLD panel.  At this time the         |
| operator attempted to test fire the PGLD system, however the system would    |
| not respond. The Front Line Mgr. and the PSS were immediately notified of    |
| the system failure.  At this time, required TSR 2.4.4.1 LCO continuous smoke |
| watches were put in place in the affected areas until repair of the system   |
| was completed.  Following replacement of the power supply by Instrument      |
| Maintenance and testing by Operations, ten Unit 4 Cell 4 PGLD system was     |
| declared operable by the PSS at 2340 CST. At this time the TSR required      |
| smoke watches were discontinued.                                             |
|                                                                              |
| "The PGLD system is designed to detect the leakage of process gas from the   |
| process system and is required to be operable while operating in Cascade     |
| Mode 2 (Above Atmospheric Pressure).  Due to the failure of this TSR         |
| required system; the PSS has determined that this is reportable as a 24 hour |
| Event Report.                                                                |
|                                                                              |
| "The NRC Resident inspector has been notified of this event."                |
|                                                                              |
| * * * RETRACTED AT 0346 EST ON 02/22/02 BY ERIC WALKER TO FANGIE JONES * * * |
|                                                                              |
|                                                                              |
| "This event has been retracted. Even though the power loss causes the system |
| to be incapable of annunciating additional alarms from this system in the    |
| ACR, the same is true when a PGLD head actuates in response to smoke. The    |
| system Is designed to alert operators of a release or loss of system power.  |
| Operator response and the initiation of a smoke watch provide the safety     |
| function after the initial alarm is annunciated. The NRC resident inspector  |
| has been notified of this update."                                           |
|                                                                              |
| The R3DO (Bruce Jorgensen) and NMSS EO (E. William Brach) have been          |
| notified.                                                                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38716       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  UTAH DIVISION OF RADIATION CONTROL   |NOTIFICATION DATE:
02/22/2002|
|LICENSEE:  ENVIROCARE OF UTAH, INC.             |NOTIFICATION TIME: 13:58[EST]|
|    CITY:  SALT LAKE CITY           REGION:  4  |EVENT DATE:        02/21/2002|
|  COUNTY:                            STATE:  UT |EVENT TIME:             [MST]|
|LICENSE#:  UT 2300249            AGREEMENT:  Y  |LAST UPDATE DATE:  02/22/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |LINDA HOWELL         R4      |
|                                                |DOUG BROADDUS                |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JULIE FELICE (VIA FAX)       |                             |
|  HQ OPS OFFICER:  STEVE SANDIN                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT INVOLVING POTENTIAL SALE OF CONTAMINATED
TOOLS TO THE |
| GENERAL PUBLIC                                                               |
|                                                                              |
| The Utah Department of Environmental Quality issued an Information Notice on |
| February 21, 2002, (text below)  concerning the potential of radiologically  |
| contaminated tools in Tooele County.                                         |
|                                                                              |
| "A recent investigation involving Envirocare of Utah, a commercial low-level |
| radioactive waste site in western Tooele County, has revealed that a former  |
| employee of Envirocare's contractor, Broken Arrow Inc., removed contaminated |
| tools that were to be disposed of as waste from the Envirocare facility and  |
| eventually sold the tools to Oquirrh Trading Company, a pawn shop located in |
| Tooele, Utah.  Records of the Trading Company have revealed the potential    |
| for a number of tools to have been sold to the public.  The period of time   |
| of concern is from January to December 2001.  The tools involved may include |
| large ratchet and socket sets, large crescent wrenches and other hand tools. |
| The tools may or may not be marked with U.S., U.S. CCC, US EC and may be     |
| painted red.  Some of these contaminated tools were recently recovered by    |
| inspectors of the Division of Radiation Control at the Trading Company.      |
| Citizens who may have purchased tools at the Trading Company during the      |
| period January 2001 - December 2001 may have their tools assessed at the     |
| Tooele County Health Department, 151 North Main, Tooele beginning Wednesday, |
| February 27, 2002, from 10:00 am. - 5:00 p.m., Thursday, February 28, 2002,  |
| and Monday, March 4, 2002, from 1:00 p.m. - 7:00 p.m..  Tools suspected to   |
| be contaminated should be handled as little as possible and wrapped in a     |
| plastic bag to be brought to the Health Department offices for assessment.   |
| Persons handling suspected tools should wash their hands afterwards.  If     |
| tools are determined to be contaminated, local and state environmental       |
| health officials will arrange for their proper disposal.                     |
|                                                                              |
| "'While we do not believe these contaminated tools present any significant   |
| health threat to members of the public, it is prudent to make sure that      |
| these tools are rounded up and properly disposed,' said Bill Sinclair,       |
| Director of the Division of Radiation Control.   'We are happy to provide    |
| facilities and cooperate with the Department of Environmental Quality in     |
| assuring that our Tooele citizens can have the opportunity to assess if      |
| there is a problem with tools that may have been purchased at the Trading    |
| Company,' stated Myron Batman of the Tooele County Health Department.        |
|                                                                              |
| "Division of Radiation Control inspectors have visited all pawn shops in     |
| Tooele County and are satisfied that this problem is confined to the one     |
| business.  The investigation is continuing and if the problem is more        |
| widespread, additional information will be issued as necessary."             |
|                                                                              |
| UT Event Report ID No.:  UT-02-0001.  Call the Headquarters Operations       |
| Officer for contact information.                                             |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Hospital                                         |Event Number:   38717       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  DANBURY HOSPITAL                     |NOTIFICATION DATE: 02/22/2002|
|LICENSEE:  DANBURY HOSPITAL                     |NOTIFICATION TIME: 16:11[EST]|
|    CITY:  NORWALK                  REGION:  1  |EVENT DATE:        02/22/2002|
|  COUNTY:  FAIRFIELD                 STATE:  CT |EVENT TIME:        14:00[EST]|
|LICENSE#:  06854401              AGREEMENT:  N  |LAST UPDATE DATE:  02/22/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |MICHAEL MODES        R1      |
|                                                |FRED BROWN           NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  CARNIE GEE                   |                             |
|  HQ OPS OFFICER:  GERRY WAIG                   |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|LADM 35.33(a)            MED MISADMINISTRATION  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MEDICAL MISADMINISTRATION INVOLVING UNDERDOSE TO CANCER PATIENT             
|
|                                                                              |
| A female patient undergoing brachytherapy treatment for cancer at the        |
| Danbury Hospital in Norwalk, CT, was prescribed 4600 Rad using a Cs-137      |
| source.  One of the five seeds (21.23 mg Radium equivalent) was found in a   |
| trash can.  This resulted in an estimated delivered dose of 3458 Rad which   |
| is 24.8% less than prescribed.  All hospital staff entering the area where   |
| the trash can was located had personal dosimetry such that no unmonitored    |
| exposures occurred.  The licensee is conducting a review to determine        |
| appropriate corrective actions.  The prescribing physician has been informed |
| by the hospital.  The licensee notified RI Office(Bhalla).  Call the         |
| Headquarters Operations Officer for contact information.                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38718       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: POINT BEACH              REGION:  3  |NOTIFICATION DATE: 02/22/2002|
|    UNIT:  [] [2] []                 STATE:  WI |NOTIFICATION TIME: 17:18[EST]|
|   RXTYPE: [1] W-2-LP,[2] W-2-LP                |EVENT DATE:        02/22/2002|
+------------------------------------------------+EVENT TIME:        14:48[CST]|
| NRC NOTIFIED BY:  MIKE MEYER                   |LAST UPDATE DATE:  02/22/2002|
|  HQ OPS OFFICER:  GERRY WAIG                   +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |BRUCE JORGENSEN      R3      |
|10 CFR SECTION:                                 |                             |
|ASHU 50.72(b)(2)(i)      PLANT S/D REQD BY TS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       100      Power Operation  |80       Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNIT 2 COMMENCED A TS REQUIRED SHUTDOWN AFTER DECLARING A SI PUMP           
|
| INOPERABLE                                                                   |
|                                                                              |
| "On February 20, 2002, at approximately 0100 CST. OI-163, 'SI, RHR, and CS   |
| Pump Runs,' was being performed on Safety Injection (SI) pump 2P-15B. This   |
| procedure is used to bump the pump to ensure bearing lubrication as a        |
| preventive maintenance activity. When the pump was started, motor current    |
| increased as normal, but then decayed to less than 10 amps. Additionally,    |
| the pump appeared to develop no discharge pressure. In the field, the        |
| auxiliary operator noted a loud bang near the end of the coastdown and       |
| further noted excessive seal leakage. At approximately 0105 CST, SI pump     |
| 2P-15B was declared inoperable, LCO 3.5.2 was declared not met, and TS       |
| Action Condition A.1 was entered. Tech Spec LCO 3.5.2. ECCS-Operating,       |
| requires two ECCS trains to be operable in Modes 1, 2, and 3. LCO 3.5.2,     |
| Condition A, requires an inoperable ECCS train to be restored to an operable |
| status within 72 hours.                                                      |
|                                                                              |
| "Subsequent inspection of the pump following disassembly of the casing       |
| revealed damage to the rotating element, the coupling and shaft keys between |
| the pump and the motor, the pump internal wear rings, and other components.  |
| At this time, we believe the pump damage was due to gas binding in the pump  |
| as a result of back leakage through two check valves. This allowed nitrogen  |
| saturated water from the 'A' SI accumulator to migrate to the 2P-15B pump.   |
| Repair of the pump has proceeded with the expectation that the pump would be |
| repaired, tested and returned to service prior to the expiration of the 72   |
| hours allowed in the action statement. However, as of approximately 1400     |
| CST, we determined that we were unlikely to complete the remaining repairs   |
| and the required pump testing before the expiration of the action statement. |
| Accordingly, at that time activities were initiated to commence a shutdown   |
| of PBNP Unit 2 and at approximately 1448 CST the shutdown of the unit was    |
| initiated."                                                                  |
|                                                                              |
| The licensee is decreasing power at 30%/hr and anticipates entry into Mode 3 |
| at approximately 1930CST.   The licensee informed the NRC Resident           |
| Inspector.                                                                   |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38719       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: TURKEY POINT             REGION:  2  |NOTIFICATION DATE: 02/22/2002|
|    UNIT:  [3] [] []                 STATE:  FL |NOTIFICATION TIME: 17:34[EST]|
|   RXTYPE: [3] W-3-LP,[4] W-3-LP                |EVENT DATE:        02/22/2002|
+------------------------------------------------+EVENT TIME:        15:00[EST]|
| NRC NOTIFIED BY:  B. ADAMS                     |LAST UPDATE DATE:  02/22/2002|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |LEONARD WERT         R2      |
|10 CFR SECTION:                                 |                             |
|ACOM 50.72(b)(3)(xiii)   LOSS COMM/ASMT/RESPONSE|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|3     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LOSS OF ASSESSMENT CAPABILITY DUE TO FAILURE OF THE ERDADS SYSTEM           
|
|                                                                              |
| "A failure of the ERDADS [Emergency Response Data Acquisition and Display    |
| System] computer due to errors in the primary and backup systems.  This      |
| resulted in the loss of all ERDADS data.  The failure also resulted in the   |
| loss of offsite communications capability (ERDADS link)."                    |
|                                                                              |
| The licensee informed the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   38720       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PADUCAH GASEOUS DIFFUSION PLANT      |NOTIFICATION DATE: 02/23/2002|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 10:58[EST]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        02/22/2002|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        16:30[CST]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  02/23/2002|
|    CITY:  PADUCAH                  REGION:  3  +-----------------------------+
|  COUNTY:  McCRACKEN                 STATE:  KY |PERSON          ORGANIZATION |
|LICENSE#:  GDP-1                 AGREEMENT:  Y  |BRUCE JORGENSEN      R3      |
|  DOCKET:  0707001                              |E. WILLIAM BRACH     NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  WHITE                        |                             |
|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NONR                     OTHER UNSPEC REQMNT    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| ACTIVATION OF THE WATER INVENTORY CONTROL SYSTEM                             |
|                                                                              |
| At 1630 CST, on 2/22/02 the Plant Shift Superintendent (PSS) was notified of |
| an activation of the Water Inventory Control System (WICS) on #1 autoclave   |
| in the C-360 building.   Approximately 50 minutes into the heat cycle, the   |
| Hi Primary Condensate alarm was received, and steam supply to the autoclave  |
| was automatically isolated.  Operators investigated the alarm.  The          |
| autoclave was removed from service, and the WICS was declared inoperable.    |
| Further investigation will be performed by the System Engineer and           |
| Instrument Maintenance to determine the exact cause of the alarm.  The       |
| purpose of the WICS is to limit the amount of water in the autoclave and is  |
| a safety system required by TSR 2.1.4.3.                                     |
|                                                                              |
| The PSS determined that this event is a 24 Hour Event Report due to a valid  |
| automatic activation of a Q safety system.                                   |
|                                                                              |
| The NRC Senior Resident Inspector has been notified of this event.           |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38721       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: INDIAN POINT             REGION:  1  |NOTIFICATION DATE: 02/23/2002|
|    UNIT:  [2] [] []                 STATE:  NY |NOTIFICATION TIME: 16:40[EST]|
|   RXTYPE: [2] W-4-LP,[3] W-4-LP                |EVENT DATE:        02/23/2002|
+------------------------------------------------+EVENT TIME:        16:25[EST]|
| NRC NOTIFIED BY:  PHIL SANTINI                 |LAST UPDATE DATE:  02/23/2002|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |MICHAEL MODES        R1      |
|10 CFR SECTION:                                 |MICHAEL CASE         NRR     |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION TO STATE POLICE                                         |
|                                                                              |
| "At 10:45, [the Control Room] received notification from Shift Security      |
| Supervisor that at 09:45 a security officer on duty in the central alarm     |
| station was escorted offsite and remanded to State Police for questioning    |
| following an apparent incident of horseplay with a duty weapon.  The         |
| security officer surrendered his weapons to company security personnel and   |
| was immediately relieved of duty.  The Shift Security Supervisor notified    |
| the USNRC Region I security inspector at approximately 11:00.  The security  |
| force remained fully staffed throughout this event and remains fully         |
| staffed."                                                                    |
|                                                                              |
| The licensee determined that the notification to the State Police was        |
| reportable as an offsite notification per 10CFR50.72(b)(2)(xi) at 1625EST.   |
| The NRC Resident Inspector was informed of this report by the licensee.      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38722       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HATCH                    REGION:  2  |NOTIFICATION DATE: 02/25/2002|
|    UNIT:  [1] [] []                 STATE:  GA |NOTIFICATION TIME: 04:25[EST]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        02/25/2002|
+------------------------------------------------+EVENT TIME:        04:15[EST]|
| NRC NOTIFIED BY:  STONE                        |LAST UPDATE DATE:  02/25/2002|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |LEONARD WERT         R2      |
|10 CFR SECTION:                                 |                             |
|ACOM 50.72(b)(3)(xiii)   LOSS COMM/ASMT/RESPONSE|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       95       Power Operation  |95       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SAFETY PARAMETER DISPLAY SYSTEM (SPDS) OUT OF SERVICE                        |
|                                                                              |
| The SPDS was removed from service for the purpose of implementing a          |
| modification to replace the system.  The primary means of monitoring the     |
| critical parameters remains available to the operating crew and they will    |
| continue to be able to perform the necessary actions regarding emergency     |
| assessment.                                                                  |
|                                                                              |
| The NRC Resident Inspector will be notified.                                 |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Wednesday, March 24, 2021