Event Notification Report for June 8, 2001

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           06/07/2001 - 06/08/2001

                              ** EVENT NUMBERS **

38008  38055  38057  38058  

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   38008       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT   |NOTIFICATION DATE: 05/18/2001|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 12:32[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        05/18/2001|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        11:18[EDT]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  06/07/2001|
|    CITY:  PIKETON                  REGION:  3  +-----------------------------+
|  COUNTY:  PIKE                      STATE:  OH |PERSON          ORGANIZATION |
|LICENSE#:  GDP-2                 AGREEMENT:  N  |GARY SHEAR           R3      |
|  DOCKET:  0707002                              |FRED BROWN           NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  MCCLEARY                     |                             |
|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NBNL                     RESPONSE-BULLETIN      |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| 4 HOUR 91-01 BULLETIN                                                        |
|                                                                              |
| During normal operations, a concern was identified of a potential fissile    |
| material operation in equipment that had been previously identified as an    |
| operation that contained material <1 % U-235.  Upon investigation of the     |
| concern Nuclear Criticality Safety Personnel identified an unanalyzed        |
| condition in the X-330/333 "A" booster. Based on the identified condition    |
| this is a 4 hour reportable event.  Currently the equipment is isolated.  A  |
| sample shows the equipment contains material at <1% U-235.                   |
|                                                                              |
| SAFETY SIGNIFICANCE OF EVENTS:                                               |
|                                                                              |
| LOW. the equipment is shutdown and has a pressure of 0.8 psia. The maximum   |
| mass in the X-330 to X-333 "A" compressor at this pressure is 41 gram U-235  |
|                                                                              |
| POTENTIAL CRITICALITY PATHWAYS INVOLVED (BRIEF SCENARIO[S] OF HOW            |
| CRITICALITY COULD OCCUR):                                                    |
|                                                                              |
| For a criticality to occur, the mass in the compressor would have to         |
| increase to greater than 10.35 kg. The material then would have to be        |
| moderated and the deposit would have to reflected                            |
|                                                                              |
| CONTROLLED PARAMETERS (MASS, MODERATION, GEOMETRY. CONCENTRATION, ETC.):     |
|                                                                              |
| Enrichment and Mass                                                          |
|                                                                              |
| ESTIMATED AMOUNT, ENRICHMENT, FORM OF LICENSED MATERIAL (INCLUDE PROCESS     |
| LIMIT AND % WORST CASE OF CRITICAL MASS):                                    |
|                                                                              |
| Estimated enrichment is 1.5 weight percent U-235, the mass is estimated at   |
| 41 grams. The form of the material would be UF6. The optimum safe mass and   |
| critical mass at an enrichment of 1.5 % U-235 is 4.5 Kg and 16.502 Kg        |
| respectively.                                                                |
|                                                                              |
| NUCLEAR CRITICALITY SAFETY CONTROL(S) OR CONTROL SYSTEM(S) AND DESCRIPTION   |
| OF THE FAILURES OR DEFICIENCIES                                              |
|                                                                              |
| There were no NCSA controls on the identified equipment because the          |
| enrichment in the equipment was to be less than 1 weight percent U-235 in an |
| operating cascade.  In the current configuration it is not credible that     |
| enrichment would be exceeded.  The deficiency was the equipment was not      |
| isolated from equipment that is allowed to see enrichment greater than 1     |
| weight percent U-235.                                                        |
|                                                                              |
| CORRECTIVE ACTIONS TO RESTORE SAFETY SYSTEM AND WHEN EACH WAS IMPLEMENTED:   |
|                                                                              |
| The Plant Shift Superintendent directed the "A" booster isolated.  The       |
| equipment was sampled and found below 1% U-235.  Engineering continues to    |
| investigate the issue.                                                       |
|                                                                              |
| The NRC Resident Inspector was notified and the DOE Representative will be   |
| informed.                                                                    |
|                                                                              |
|                                                                              |
| * * * UPDATE ON 06/07/01 AT 1313 ET BY RICHIE TAKEN BY MACKINNON * * *       |
|                                                                              |
| After further review this is not reportable because an additional evaluation |
| determined the enrichment in the affected equipment did not exceed 1 weight  |
| percent U235, and the plant condition remained within that assumed by the    |
| NCSA and SAR.  Therefore no violation occurred.  R3DO (B. Clayton) & NMSS EO |
| (John Hickey) notified.                                                      |
|                                                                              |
| The NRC Resident Inspector was notified of this update by the Certificate    |
| Holder.                                                                      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38055       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  NEW YORK CITY BUREAU OF RAD HEALTH   |NOTIFICATION DATE: 06/06/2001|
|LICENSEE:  UNKNOWN                              |NOTIFICATION TIME: 17:37[EDT]|
|    CITY:  QUEENS                   REGION:  1  |EVENT DATE:        06/04/2001|
|  COUNTY:  QUEENS                    STATE:  NY |EVENT TIME:             [EDT]|
|LICENSE#:                        AGREEMENT:  Y  |LAST UPDATE DATE:  06/07/2001|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |MICHELE EVANS        R1      |
|                                                |M. WAYNE HODGES      NMSS    |
+------------------------------------------------+JOSEPH HOLONICH      IRO     |
| NRC NOTIFIED BY:  RICHARD BORRI                |DOT NATL RESP CTR            |
|  HQ OPS OFFICER:  BOB STRANSKY                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT REGARDING PACKAGE DAMAGED DURING OVERSEA SHIPMENT     |
|                                                                              |
| The New York City Bureau of Radiological Health was contacted on 6/6/2001 by |
| a Japan Airlines (JAL) representative regarding a damaged shipment of 104    |
| �Ci of I-125 (liquid).  The package was being shipped from New England       |
| Nuclear in Boston, Massachusetts to China Isotope Corporation in Beijing,    |
| China.  The package had been transported by truck to JFK Int'l Airport,      |
| where it was loaded onto a JAL aircraft.  The JAL representative reported    |
| that the package was badly damaged and leaking upon arrival in Tokyo, Japan. |
| Representatives of the Bureau of Radiological Health and Radiac (a           |
| contractor for JAL) surveyed the building at JFK Int'l Airport where the     |
| package had been stored, but found no radioactive contamination. The caller  |
| was unsure of actions taken at the airport in Tokyo.                         |
|                                                                              |
| HOO NOTE: Provided above information to the DOT National Response Center.    |
|                                                                              |
|                                                                              |
| * * * UPDATE ON 6/7/01 @ 1132 BY BORRI TO GOULD * * *                        |
|                                                                              |
| A JAL representative notified New York City Bureau of Radiological Health    |
| that they measured 4000 cpm in the freight container at the Tokyo airport.   |
| Also a worker at the JFK airport admitted that he broke the package when     |
| loading it on the plane.                                                     |
|                                                                              |
| Notified REG 1 RDO(Evans) and NMSS EO(Hickey)                                |
|                                                                              |
| * * * UPDATE 1518EDT ON 6/7/01 FROM BOB GALLAGHAR TO S. SANDIN * * *         |
|                                                                              |
| "Date: June 7, 2001                                                          |
|                                                                              |
| "Update Information from Massachusetts Radiation Control Program             |
| "Provided by Robert Gallaghar, Supervisor Inspection & Enforcement,          |
| Materials Section                                                            |
|                                                                              |
|                                                                              |
| "PACKAGE DAMAGED DURING OVERSEA SHIPMENT                                     |
|                                                                              |
| "The package was being shipped from PerkinElmer Life Sciences in Boston,     |
| Massachusetts to China Isotope Corporation in Beijing, China.  The package   |
| contained 130 mCi (4.8 GBq) iodine-125 as NaI in < 1 ml liquid.   External   |
| radiation measurement imply that 1 to 30 mCi of I-125 may have been released |
| from the shielded container into the surrounding packaging material.  The    |
| package was secured in a plastic bag and held in a cordoned off area.        |
|                                                                              |
| "On June 6, 2001 a contamination survey was performed of the JAL facility at |
| JFK and confirmed no contamination.  JAL representatives confirmed that the  |
| incident was promptly reported to the Japan Bureau of Radiation Protection.  |
| An inspector from the Japan Radioisotope Association has made radiation and  |
| contamination surveys.                                                       |
|                                                                              |
| "The package was one of several in a 3.8 cubic meter shipping container.  A  |
| radiation reading of 3.8 mr/hr at 1 meter was reported outside the lead      |
| shielding.  JAL representatives have informed PerkinElmer there were two     |
| spots of contamination, one on the floor of the container and one on a       |
| pallet, both places having been in contact with the package.  No other       |
| contamination was found in the area or on any persons."                      |
|                                                                              |
| The Massachusetts Radiation Control Program informed NRC Region I (Duncan    |
| White).  Notified R1DO(Evans) and NMSS(Susan Frant).                         |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38057       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: POINT BEACH              REGION:  3  |NOTIFICATION DATE: 06/07/2001|
|    UNIT:  [1] [2] []                STATE:  WI |NOTIFICATION TIME: 20:53[EDT]|
|   RXTYPE: [1] W-2-LP,[2] W-2-LP                |EVENT DATE:        06/07/2001|
+------------------------------------------------+EVENT TIME:        18:30[CDT]|
| NRC NOTIFIED BY:  J. GADZALA                   |LAST UPDATE DATE:  06/07/2001|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |BRENT CLAYTON        R3      |
|10 CFR SECTION:                                 |                             |
|AUNA 50.72(b)(3)(ii)(B)  UNANALYZED CONDITION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| POTENTIAL NON-CONSERVATISM IN MAIN STEAM LINE BREAK ACCIDENT IDENTIFIED      |
| DURING REACTOR POWER UPDATE ANALYSES                                         |
|                                                                              |
| "During preparation of a new analyses for reactor power uprate, a potential  |
| non-conservatism was discovered regarding the main steam line break accident |
| with an assumed single failure of a main feedwater regulating valve. This    |
| non-conservatism could negatively impact the resultant peak containment      |
| pressure that would be reached in the event of an accident. The current      |
| Point Beach accident analysis does not appear to properly account for the    |
| volume of high temperature feedwater that would be released inside           |
| containment during a main steam line break accident. It does not appear to   |
| correctly model failure of the feedwater regulating valve to close.          |
|                                                                              |
| "Based on the revised analyses performed by the reactor vendor               |
| (Westinghouse) at the uprated power conditions, peak containment pressure    |
| could reach 64.2 psig. No revised analysis data is yet available for the     |
| currently licensed power level; however, the uprated analysis bounds the     |
| current plant design. The 64.2 psig value exceeds the containment design     |
| pressure of 60 psig.                                                         |
|                                                                              |
| "The Bases for Technical Specification 1 5.3.6.A.1 .a states,  The safety    |
| design basis for the containment is that the containment must withstand the  |
| pressures and temperatures of the design basis LOCA without exceeding the    |
| design leakage rate. The design allowable leakage rate La is 0.4% of         |
| containment air weight per day at 60 psig .  Containment operability is      |
| maintained by limiting the overall containment leakage rate to within the    |
| design allowable leakage rage (La).                                          |
|                                                                              |
| "FSAR section 5.1 documents that the containment can withstand pressure      |
| loadings at least 50% greater than those calculated for the postulated       |
| loss-of-coolant accident alone, and 25% greater than those calculated for    |
| the postulated loss-of-coolant accident with a coincident design earthquake  |
| (FSAR 14.3.4 states that containment pressure will peak between 52 and 54    |
| psig).                                                                       |
|                                                                              |
| "Since the revised analysis is only for uprated power conditions, it does    |
| not exactly predict containment pressure results at the current licensed     |
| power level. However, the new analysis calls the results of the current      |
| analysis into question. Therefore, this report is being conservatively made  |
| to document this concern. The containment has been determined to be operable |
| per the guidelines of Generic Letter 91-18. Mitigating circumstances include |
| the fact that calculations in the FSAR document that the containment is      |
| capable of withstanding the higher pressure of the revised analysis.         |
|                                                                              |
| "The containment will continue to perform its safety function. Any           |
| radiological release during a main steam line break accident is assumed to   |
| vent directly to the atmosphere (through the break), independent of          |
| containment integrity and is within current analyses."                       |
|                                                                              |
| Westinghouse is performing a reanalysis with corrective actions to be        |
| determined.  The licensee informed the NRC resident inspector.               |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38058       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DUANE ARNOLD             REGION:  3  |NOTIFICATION DATE: 06/08/2001|
|    UNIT:  [1] [] []                 STATE:  IA |NOTIFICATION TIME: 00:41[EDT]|
|   RXTYPE: [1] GE-4                             |EVENT DATE:        06/07/2001|
+------------------------------------------------+EVENT TIME:        21:33[CDT]|
| NRC NOTIFIED BY:  ROBINSON                     |LAST UPDATE DATE:  06/08/2001|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |BRENT CLAYTON        R3      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       47       Power Operation  |47       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| HPCI DECLARED INOPERABLE DUE TO A FAULTY FLOW INDICATING SWITCH              |
|                                                                              |
| With DAEC operating in mode 1, at approximately 47% power, HPCI was declared |
| inoperable due to a faulty flow indicating switch which is utilized to       |
| position the minimum flow valve.  A 14-day LCO was entered per Technical     |
| Specification 3.5.1, condition F, at 2133 on 6/7/01.  This condition is      |
| reportable under 50.72(b)(3)(v)(D) and 50.73(a)(2)(v)(D) as a failure of a   |
| single train of equipment required to mitigate the consequences of an        |
| accident.                                                                    |
|                                                                              |
| While an in-plant operator was performing his rounds within the HPCI room,   |
| he discovered that flow indicating switch, FS2310, which should indicate     |
| total HPCI flow, indicated approximately -170 gpm rather than the expected   |
| zero gpm.  The HPCI pump was not in operation.  This flow switch is          |
| interlocked with the HPCI minimum flow valve, allowing it to open with total |
| HPCI flow less than 300 gpm and HPCI discharge pressure greater than 125     |
| psig.  The flow switch would close the minimum flow valve once HPCI total    |
| flow reached 600 gpm.  With the correct operation of the HPCI minimum flow   |
| valve in question, HPCI was declared inoperable.                             |
|                                                                              |
| It is believed that the cause of the faulty indication is air in the         |
| instrument sensing lines feeding the flow switch. Troubleshooting efforts    |
| will begin early tomorrow morning.                                           |
|                                                                              |
| The NRC Resident Inspector was notified                                      |
|                                                                              |
|                                                                              |
| HOO NOTE:  see event #38029                                                  |
+------------------------------------------------------------------------------+
