Event Notification Report for March 1, 2001

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           02/28/2001 - 03/01/2001

                              ** EVENT NUMBERS **

37785  37786  37787  37788  37789  37791  37792  37793  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37785       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SEABROOK                 REGION:  1  |NOTIFICATION DATE: 02/28/2001|
|    UNIT:  [1] [] []                 STATE:  NH |NOTIFICATION TIME: 09:55[EST]|
|   RXTYPE: [1] W-4-LP                           |EVENT DATE:        02/27/2001|
+------------------------------------------------+EVENT TIME:        11:45[EST]|
| NRC NOTIFIED BY:  MORRISSEY                    |LAST UPDATE DATE:  02/28/2001|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |RICHARD CONTE        R1      |
|10 CFR SECTION:                                 |                             |
|HFIT 26.73               FITNESS FOR DUTY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| ACTUAL INTRODUCTION OF CONTRABAND INTO THE PROTECTED AREA.                   |
|                                                                              |
| Immediate compensatory measures were taken upon discovery.                   |
|                                                                              |
| Contact the HOO for additional information.                                  |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   37786       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  MISSISSIPPI DIV OF RAD HEALTH        |NOTIFICATION DATE: 02/28/2001|
|LICENSEE:  GE INSPECTION SERVICES               |NOTIFICATION TIME: 12:30[EST]|
|    CITY:                           REGION:  2  |EVENT DATE:        02/28/2001|
|  COUNTY:                            STATE:  MS |EVENT TIME:        10:30[CST]|
|LICENSE#:  MS863-01              AGREEMENT:  Y  |LAST UPDATE DATE:  02/28/2001|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |STEPHEN CAHILL       R2      |
|                                                |                             |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  B. J. SMITH                  |                             |
|  HQ OPS OFFICER:  BOB STRANSKY                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| POSSIBLE OVEREXPOSURE OF RADIOGRAPHER                                        |
|                                                                              |
| The licensee notified the State of Mississippi that the TLD reading for an   |
| employee during the period of January 2001 was 14.624 rem. However, the TLD  |
| readings for the radiographer's assistants during the same period were       |
| normal, and the individual's pocket dosimeter indicated a total dose of      |
| approximately 350 mrem during the period. The licensee's RSO is              |
| investigating this event.                                                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37787       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DIABLO CANYON            REGION:  4  |NOTIFICATION DATE: 02/28/2001|
|    UNIT:  [1] [2] []                STATE:  CA |NOTIFICATION TIME: 14:40[EST]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        02/28/2001|
+------------------------------------------------+EVENT TIME:             [PST]|
| NRC NOTIFIED BY:  STEVEN DAVID                 |LAST UPDATE DATE:  02/28/2001|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |LINDA HOWELL         R4      |
|10 CFR SECTION:                                 |                             |
|*PRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION DUE TO DISCOVERY OF THREATENED SPECIES ONSITE           |
|                                                                              |
| The licensee notified the National Marine Fisheries Service that a live      |
| green sea turtle was discovered in the plant intake structure. The turtle    |
| was released into the Pacific Ocean. The NRC resident inspector has been     |
| informed of this event by the licensee.                                      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37788       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUMMER                   REGION:  2  |NOTIFICATION DATE: 02/28/2001|
|    UNIT:  [1] [] []                 STATE:  SC |NOTIFICATION TIME: 14:42[EST]|
|   RXTYPE: [1] W-3-LP                           |EVENT DATE:        01/12/2001|
+------------------------------------------------+EVENT TIME:        12:08[EST]|
| NRC NOTIFIED BY:  KELLEY MARSH                 |LAST UPDATE DATE:  02/28/2001|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |STEPHEN CAHILL       R2      |
|10 CFR SECTION:                                 |VERN HODGE           NRR     |
|CCCC 21.21               UNSPECIFIED PARAGRAPH  |RICHARD CONTE        R1      |
|                                                |ANTON VEGEL          R3      |
|                                                |LINDA HOWELL         R4      |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Refueling        |0        Startup          |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| 10 CFR  PART 21 REPORT REGARDING A SUBSTANTIAL SAFETY HAZARD WITH A WOODWARD |
| GOVERNOR EGB UNIT                                                            |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "On 1/12/01, V. C. Summer Nuclear Station (VCSNS) determined that a          |
| Substantial Safety Hazard could exist with Woodward governor EGB units       |
| failing to properly control the Emergency Diesel Generator [(EDG)].  A       |
| condition report (received on 1/12/01) from B. F. Goodrich/Fairbanks Morse   |
| indicated there was binding of the terminal shaft internal to an EGB unit    |
| removed from the 'A' EDG at VCSNS.  The disassembly inspection found that    |
| the binding of the terminal shaft was due to the use of clamping screws,     |
| which were 1/8 inch longer than specification, resulting in binding on the   |
| output servo piston connecting rod.                                          |
|                                                                              |
| "This error was made during the prior refurbishment of the EGB by Engine     |
| Systems Inc. (ESI), the Woodward Governor nuclear representative, on         |
| 2/24/00.  The use of the longer screws resulting in binding in the unit is   |
| considered a defect, which was introduced during the repair process by ESI.  |
|                                                                              |
| "[VCSNS] utilizes these EGB units on both the 'A' and 'B' EDGs.  The above   |
| condition produced severe frequency oscillations on the output of the 'A'    |
| EDG.  This condition could have been introduced to any EGB during            |
| refurbishment by ESI, passed acceptance testing, and be present on both      |
| EDGs.  In an emergency condition, both EDGs could fail, resulting in the     |
| loss of safety function for the emergency on-site power supply.              |
|                                                                              |
| "The EGB units currently installed on both EDGs have been refurbished by     |
| Fairbanks Morse with properly specified parts.  Fairbanks Morse will perform |
| all future EGB refurbishment work for VCSNS.  Other cause and corrective     |
| actions associated with the governor issues are being addressed under Root   |
| Cause Analysis report RCA 01-0235, 'Diesel Generator 'A' Governor Problems.' |
| "                                                                            |
|                                                                              |
| The licensee notified the NRC resident inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37789       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COLUMBIA GENERATING STATIREGION:  4  |NOTIFICATION DATE: 02/28/2001|
|    UNIT:  [2] [] []                 STATE:  WA |NOTIFICATION TIME: 15:13[EST]|
|   RXTYPE: [2] GE-5                             |EVENT DATE:        02/28/2001|
+------------------------------------------------+EVENT TIME:        10:57[PST]|
| NRC NOTIFIED BY:  MIKE KELLER                  |LAST UPDATE DATE:  02/28/2001|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |LINDA HOWELL         R4      |
|10 CFR SECTION:                                 |CHARLES MILLER       IRO     |
|NINF                     INFORMATION ONLY       |ED GOODWIN           NRR     |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| EARTHQUAKE FELT ONSITE                                                       |
|                                                                              |
| At 1057PST an earthquake in Western Washington State with a magnitude of 7.0 |
| was felt onsite.  The epicenter  is located 11.3 miles NE of Olympia, WA and |
| 14.9 miles West South West of Tacoma, WA.  The depth of the earthquake was   |
| 30 miles.   Seismic sensors did not detect the seismic activity. Plant       |
| inspection performed after the earthquake found no abnormal conditions.      |
|                                                                              |
| The NRC Resident Inspector was notified of this information call by the      |
| licensee.                                                                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37791       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUMMER                   REGION:  2  |NOTIFICATION DATE: 03/01/2001|
|    UNIT:  [1] [] []                 STATE:  SC |NOTIFICATION TIME: 03:19[EST]|
|   RXTYPE: [1] W-3-LP                           |EVENT DATE:        03/01/2001|
+------------------------------------------------+EVENT TIME:        00:17[EST]|
| NRC NOTIFIED BY:  SIMPSON                      |LAST UPDATE DATE:  03/01/2001|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |STEPHEN CAHILL       R2      |
|10 CFR SECTION:                                 |                             |
|*RPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     M/R        Y       1        Startup          |0        Hot Standby      |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| REACTOR WAS MANUALLY TRIPPED AT LESS THAN 1% POWER                           |
|                                                                              |
|                                                                              |
| A manual reactor trip was initiated at 0017 on 3/01/01 due to 2 shutdown     |
| control rods remaining on the bottom while initiating control rod            |
| withdrawal.  This occurred during low power physics testing and a trouble    |
| shooting plan for a misaligned Shutdown bank B Control rod (G-9).  The rod   |
| had already been realigned to the other rods in shutdown bank B @ 43 steps.  |
| The Shutdown bank was inserted into the core to zero steps per the trouble   |
| shooting plan.   After the step counters and rod control were reset and      |
| Shutdown bank B rods were being withdrawn, it was discovered that 2 rods had |
| not moved and were still on the bottom with 14 steps demanded. The Shutdown  |
| bank was re-inserted to zero steps (fully inserted).   After further         |
| discussion, the shift supervisor called for a manual reactor trip.  The      |
| reactor operator tripped the Reactor and the Crew entered the Emergency      |
| Operation Procedures  (EOP-1.0, Reactor trip/safety injection, and EOP-1.1,  |
| Reactor trip recovery).   All systems functioned as designed.  The problem   |
| with the rod control system is not understood and trouble shooting is        |
| continuing.                                                                  |
|                                                                              |
|                                                                              |
| Note: The 2 rods that did not move were rods G-9 and L-5, both in Shutdown   |
| bank B.                                                                      |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37792       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: INDIAN POINT             REGION:  1  |NOTIFICATION DATE: 03/01/2001|
|    UNIT:  [2] [] []                 STATE:  NY |NOTIFICATION TIME: 05:42[EST]|
|   RXTYPE: [2] W-4-LP,[3] W-4-LP                |EVENT DATE:        03/01/2001|
+------------------------------------------------+EVENT TIME:        05:00[EST]|
| NRC NOTIFIED BY:  KICH                         |LAST UPDATE DATE:  03/01/2001|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |RICHARD CONTE        R1      |
|10 CFR SECTION:                                 |                             |
|*PRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| THE LICENSEE NOTIFIED STATE AND COUNTY OFFICIALS OF A TRANSIT STRIKE IN      |
| WESTCHESTER COUNTY.                                                          |
|                                                                              |
| The licensee was notified that transit employees of the Liberty Bus Company  |
| in Westchester County will be going on strike.  The licensee made the        |
| offsite notifications to assure that the contingency plans are in effect to  |
| deal with the strike.                                                        |
|                                                                              |
| The NRC Resident Inspector will be notified.                                 |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37793       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: INDIAN POINT             REGION:  1  |NOTIFICATION DATE: 03/01/2001|
|    UNIT:  [] [3] []                 STATE:  NY |NOTIFICATION TIME: 06:33[EST]|
|   RXTYPE: [2] W-4-LP,[3] W-4-LP                |EVENT DATE:        03/01/2001|
+------------------------------------------------+EVENT TIME:        05:00[EST]|
| NRC NOTIFIED BY:  YOUNG                        |LAST UPDATE DATE:  03/01/2001|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |RICHARD CONTE        R1      |
|10 CFR SECTION:                                 |                             |
|*PRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|3     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| THE LICENSEE NOTIFIED STATE AND COUNTY OFFICIALS OF A TRANSIT STRIKE IN      |
| WESTCHESTER COUNTY.                                                          |
|                                                                              |
| The  licensee was notified that transit employees of the Liberty Bus Company |
| in Westchester County will be going on strike.  The licensee made the        |
| offsite notifications to assure that the contingency plans are in effect to  |
| deal with the strike.                                                        |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Thursday, March 25, 2021