Event Notification Report for July 19, 2000
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
07/18/2000 - 07/19/2000
** EVENT NUMBERS **
37174 37175 37176 37177
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37174 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: QUAD CITIES REGION: 3 |NOTIFICATION DATE: 07/18/2000|
| UNIT: [] [2] [] STATE: IL |NOTIFICATION TIME: 08:29[EDT]|
| RXTYPE: [1] GE-3,[2] GE-3 |EVENT DATE: 07/18/2000|
+------------------------------------------------+EVENT TIME: 05:48[CDT]|
| NRC NOTIFIED BY: NORTON |LAST UPDATE DATE: 07/18/2000|
| HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |MICHAEL PARKER R3 |
|10 CFR SECTION: | |
|ARPS 50.72(b)(2)(ii) RPS ACTUATION | |
|AESF 50.72(b)(2)(ii) ESF ACTUATION | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 A/R Y 100 Power Operation |0 Hot Standby |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| REACTOR SCRAM FROM 100% POWER DUE TO A GENERATOR LOAD REJECT FOLLOWED BY |
| TURBINE TRIP. |
| |
| THE UNIT 2 REACTOR SCRAM WAS RECEIVED DUE TO A GENERATOR LOAD REJECT |
| APPARENTLY CAUSED BY A DISTURBANCE ON THE 345 KV SYSTEM. ALL RODS FULLY |
| INSERTED, NO INJECTION INITIATED AND NO SAFETY/RELIEF VALVES LIFTED. THEY |
| ALSO HAD GROUP 2 AND GROUP 3 ISOLATIONS, AS EXPECTED, DUE TO A REACTOR WATER |
| LEVEL LOW SIGNAL FOLLOWING THE REACTOR SCRAM. THE UNIT 2 AND SHARED |
| EMERGENCY DIESEL GENERATORS AUTOSTARTED AND RAN UNLOADED AS THE RESULT OF |
| THE AUTOMATIC BUS TRANSFERS. |
| |
| UNIT 1 REMAINS AT 100% POWER WITH ITS RESERVE AUXILIARY TRANSFORMER |
| DE-ENERGIZED AND UNIT 2 IS IN MODE 3 WITH ITS NORMAL WATER LEVEL BAND. THE |
| CAUSE OF THIS EVENT, WHICH PROBABLY OCCURRED OUTSIDE THE YARD, IS STILL |
| BEING INVESTIGATED. |
| |
| THE SECTIONS OF THE RING BUS THAT THEY LOST LEFT UNIT 1 WITHOUT ITS RESERVE |
| AUXILIARY TRANSFORMER, SO IT IS RUNNING OFF ITS AUXILIARY TRANSFORMER. |
| |
| THE NRC RESIDENT INSPECTOR WAS NOTIFIED BY THE LICENSEE. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Hospital |Event Number: 37175 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: GRAND VIEW HOSPITAL |NOTIFICATION DATE: 07/18/2000|
|LICENSEE: GRAND VIEW HOSPITAL |NOTIFICATION TIME: 12:57[EDT]|
| CITY: SELLERSVILLE REGION: 1 |EVENT DATE: 06/30/2000|
| COUNTY: STATE: PA |EVENT TIME: 11:00[EDT]|
|LICENSE#: 37-13187-02 AGREEMENT: N |LAST UPDATE DATE: 07/18/2000|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |GREGORY CRANSTON R1 |
| |DON COOL NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: DAVE LIGHTFOOT | |
| HQ OPS OFFICER: DICK JOLLIFFE | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|BAB2 20.2201(a)(1)(ii) LOST/STOLEN LNM>10X | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| - GRAND VIEW HOSPITAL, SELLERSVILLE, PA, MISSING TWO 0.38 MILLICURIE I-125 |
| SEEDS - |
| |
| At 1100 on 06/30/00, Grand View Hospital, Sellersville, PA, received a |
| shipment of two vials of I-125 seeds from Imagyn Medical Technologies, |
| Lenexa, KS. The shipping papers stated that the first vial contained one |
| calibration seed and the second vial contained 81 seeds. Each seed |
| contained 0.38 millicuries of I-125. However, when hospital personnel |
| opened the vials, the second vial contained only 80 seeds instead of 81 |
| seeds. Hospital personnel notified Imagyn, the shipper, International |
| Isotopes, Benton, TX, and NRC Region 1 (Neelam Bhalla). Imagyn started an |
| investigation into the missing seed. |
| |
| On 07/17/00, Grand View Hospital received another shipment of two vials of |
| I-125 seeds from Imagyn. The shipping papers stated that the first vial |
| contained one calibration seed and the second vial contained 94 seeds. Each |
| seed contained 0.38 millicuries of I-125. However, when hospital personnel |
| opened the shipping container, the container contained only one vial, the |
| one with the calibration seed. |
| |
| Hospital personnel notified Imagyn and requested an emergency shipment of |
| the missing vial containing 94 seeds. |
| |
| At 0300 on 07/18/00, hospital personnel received the emergency shipment of |
| one vial of I-125 seeds from Imagyn. The shipping papers stated that the |
| vial contained 94 seeds. However, when hospital personnel opened the vial, |
| it contained only 93 seeds instead of 94 seeds. Hospital personnel notified |
| Imagyn and NRC Region 1 (Neelam Bhalla). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37176 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DUANE ARNOLD REGION: 3 |NOTIFICATION DATE: 07/18/2000|
| UNIT: [1] [] [] STATE: IA |NOTIFICATION TIME: 14:17[EDT]|
| RXTYPE: [1] GE-4 |EVENT DATE: 07/18/2000|
+------------------------------------------------+EVENT TIME: 12:12[CDT]|
| NRC NOTIFIED BY: BOB MURRELL |LAST UPDATE DATE: 07/18/2000|
| HQ OPS OFFICER: DICK JOLLIFFE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |MICHAEL PARKER R3 |
|10 CFR SECTION: | |
|AESF 50.72(b)(2)(ii) ESF ACTUATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| - UNEXPECTED ESF ACTUATION DURING PREPLANNED MAINTENANCE ACTIVITIES - |
| |
| At 1212 CDT on 07/18/00, during preplanned maintenance activities on the 'B' |
| standby gas treatment system logic, an unexpected, invalid ESF actuation |
| occurred. Specifically, a planned fuse removal resulted in an unexpected |
| isolation of a containment nitrogen makeup valve and a recirc minipurge |
| valve. All isolations were completed, as designed. The licensee plans to |
| restore all components to their normal positions prior to completing the |
| maintenance activities. |
| |
| The licensee notified the NRC Resident Inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37177 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: GINNA REGION: 1 |NOTIFICATION DATE: 07/18/2000|
| UNIT: [1] [] [] STATE: NY |NOTIFICATION TIME: 19:40[EDT]|
| RXTYPE: [1] W-2-LP |EVENT DATE: 07/18/2000|
+------------------------------------------------+EVENT TIME: 18:45[EDT]|
| NRC NOTIFIED BY: DOUG GOMEZ/RON TEED |LAST UPDATE DATE: 07/18/2000|
| HQ OPS OFFICER: DICK JOLLIFFE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |GREGORY CRANSTON R1 |
|10 CFR SECTION: | |
|DDDD 73.71 UNSPECIFIED PARAGRAPH | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| PHYSICAL SECURITY EVENT - |
| |
| ATTEMPTED INTRODUCTION OF CONTRABAND INTO THE PLANT PROTECTED AREA. |
| COMPENSATORY MEASURES WERE IMMEDIATELY TAKEN UPON DISCOVERY. THE LICENSEE |
| PLANS TO NOTIFY THE NRC RESIDENT INSPECTOR. CONTACT THE NRC OPERATIONS |
| OFFICER FOR ADDITIONAL DETAILS. |
+------------------------------------------------------------------------------+